PrecisionFlex® Pre-Stubbed Patch Panels

PrecisionFlex® Pre-Stubbed Patch Panels provide an additional level of customization above the pre-terminated patch panels by allowing the customer to have an entire cable stub factory installed, providing for additional customer efficiencies, improving quality, and reducing the amount of splicing in the link. Pre-Stubbed Patch Panel solutions allow the customer to specify the cable type, fiber type, fiber quantity, panel connector type, and panel size. This selection is then factory assembled, installed, and tested in a clean factory environment, and supplied in a coiled cable/panel assembly ready for deployment in the customer’s network.

Find a Distributor

Ordering Information

Instructions: Create a part number by using this character set and codes.

FT – [ 1 ] [ 2 2 2 ] [ 3 ] [ 4 ] [ 5 ] [ 6 ] [ 77 ] [ 8888 ]

[ 1 ] – Fiber Type [ 2 ] – Fiber Count [ 3 ] – Cable Type [ 4 ] – Cable Construct[ 5 ] & [ 6 ] – Panel Connector A & B   [ 7 ] – Panel Size[ 8 ] – Length*
1 – OM1 Fiber (62.5 μm)
2 – OM2 Fiber (50 μm)
3 – OM3 Fiber (50 μm)
4 – OM4 Fiber (50 μm)
5 – OM5 Fiber (50 μm)
9 – SM Fiber (G.657.A1)
024 – 24 Fibers (SC, ST & LC)
048 – 48 Fibers (SC, ST & LC)
072 – 72 Fibers (SC, ST & LC)
096 – 96 Fibers (SC, ST & LC)
144 – 144 Fibers (SC, ST & LC)
288 – 288 Fibers (SC, ST & LC)
423 – 432 Fibers (SC, ST & LC)
576 – 576 Fibers (LC Only)
864 – 864 Fibers (LC Only)
1 – Interlocking Armorer I/O Riser
2 – Interlocking Armorer
I/O Plenum
G – Indoor/Outdoor Riser
H – Interlocking Armorer Indoor Plenum
L – Interlocking Armorer Indoor Riser
P – Indoor Riser
U – Indoor Plenum
X – Jacket Not Applicable
Y – Indoor/Outdoor Plenum
Z – Low Smoke Zero Halogen
I – 900μm
W – 250μm
R – 250μm Flat Ribbon
F – 250μm Freeform Ribbon®
Y – 200μm Freeform Ribbon®
X – Not Applicable
5 – MPO(Male), 12 Fiber, Low Loss
6 – MPO(Male), 12 Fiber, Std Loss
7 – MPO(Female), 12 Fiber, Low Loss
8 – MPO(Female), 12 Fiber, Std Loss
9 – MPO(Male), 24 Fiber, Low Loss
Z – MPO(Male), 24 Fiber, Std Loss
0 – MPO(Female), 24 Fiber, Low Loss
W – MPO(Female), 24 Fiber, Std Loss
1 – MTP(Male), 12 Fiber, Low Loss
M – MTP(Male), 12 Fiber, Std Loss
2 – MTP(Female), 12 Fiber, Low Loss
Y – MTP(Female), 12 Fiber, Std Loss
4 – MTP(Male), 24 Fiber, Low Loss
P – MTP(Male), 24 Fiber, Std. Loss
3 – MTP(Female), 24 Fiber, Low Loss
N – MTP(Female), 24 Fiber, Std. Loss
L – LC, MM/SM, DX
Q – LC, MM/SM, SX
A – LC APC, DX
E – LC APC, SX
V – SC, MM/SM, SX
H – SC APC, SX
F – FC, MM/SM
C – FC APC
T – ST, MM/SM
X – Bare End (Open/Blunt)
1U – 1RU
2U – 2RU
4U – 4RU
6U – 6RU (3, 2RU’s Combined)
xxxF – Feet
xxxM – Meters
*Length maximum are dependent on cable version. Contact SEL for additional information.