Standard Ribbon Indoor Riser Central Tube Cables
Sumitomo Electric Lightwave’s Standard Ribbon Indoor Riser Central Tube Cables feature a flame-retardant outer jacket, 250μm color-coded optical fibers for easy fiber identification, and Sumitomo’s exclusive patented easy split and peel technology for easy fiber access and unprecedented ease of handling and splicing. The 12-fiber ribbon subunits enable easy connectorization with MPO splice-on connectors and ribbon pigtails. These cables are an excellent choice for intra-building connectivity applications for data centers and other network application scenarios.
Flexible dielectric strength members provide mechanical durability within a flame-retardant jacket, and the non-preferential bend axis allows for easy installation in space-constrained areas. The all-dielectric cable construction requires no grounding or bonding. The cables meet OFNR and CSA FT4 specifications and are available in all fiber types.
Product Downloads
Specifications
General | |
---|---|
Application | Indoor |
Cable Structure | Central Tube |
Ribbon Type | Standard Ribbon |
Metallic Elements | Bonding/Grounding Required |
Mechanical Characteristics | |
---|---|
Maximum Tensile Load (During Installation) | 600 lb (2,670 N) |
Maximum Recommended Service Load | 200 lb (890 N) |
Maximum Compression Resistance | 124 lb/in (220 N/cm) |
Minimum Bend Radius (During/After Installation) | 20/10 x Cable OD |
Temperature Range | |
---|---|
Operation | -4 to +158°F (-20 to +70°C) |
Storage & Shipping | 14 to +140°F (-10 to +60°C) |
Installation | -40 to +158°F (-40 to +70°C) |
Standards | |
---|---|
Standards | OFNR, FT4/UL 1666 |
Ordering Information
Fiber Count | Fiber Size | Nominal Cable OD (in | mm) | Nominal Weight (lb/kft | kg/km) | Fibers Per Ribbon |
---|---|---|---|---|
12 – 96f | 250 μm | 0.52 (13.2) | 102.0 (151.0) | 12f |
108 – 216f | 250 μm | 0.62 (15.7) | 128.0 (190.0) | 12f |
288 – 432f | 250 μm | 0.81 (20.5) | 210.0 (313.0) | 24f |
576 – 864f | 250 μm | 1.01 (25.6) | 321.0 (478.0) | 36f |
Instructions: Create a part number by using this character set & codes.
SE – [ 1 ] RP [ 2 2 2 2 ] – [ 3 ]
[ 1 ] – Fiber Type | [ 2 ] – Fiber Count (4-Digits) | [ 3 ] – Fiber Attenuation Grades |
---|---|---|
1 – 50 μm Multi-mode Fiber (OM3/OM4, 12-43f Only) 8 – PureAccess® G.657.A1 Bend Insensitive Single-Mode Fiber | 0012 – 12f 0024 – 24f 0048 – 48f 0072 – 72f 0096 – 96f 0144 – 144f 0288 – 288f 0432 – 432f 0576 – 576f 0864 – 864f | B – Standard Single-Mode 0.40/0.30 dB/km (1310/1550 nm) 7 – OM3 Enhanced performance 50 μm MM (850/1300nm) 10Gb 8 – OM4 Enhanced performance 50 μm MM (850/1300nm) 10Gb |
Accessories
Part Number | Description |
---|---|
CRC-001 | Cable Ring Tool, 0.25 – 1.625 in (4 – 28 mm) for End/Mid-Span Access |
CSC-002 | Cable Slit Tool for End/Mid-Span Access |
UCTS-001 | Central Tube Slit & Ring Tool, 0.19 – 0.73 in (4.75 – 18.5 mm) for End/Mid-Span Access |
UCTS-001-BLADE | Replacement Blade for UCTS-001 |
MA-2-REFILL | Ribbon Matrix Remover with Board & Double Sided Tape (Qty. 25) |
RS-24 | 24f Ribbon Splitter Tool |
JR-7 | Heated Jacket Remover with AC Adapter & Battery for Single-fibers & up to12-Fiber Ribbons |
JR-M03 | Jacket Remover for 250μm, 900μm, and Up to 3 mm Jacketed Single-fibers |
LYNX-SHEARS | Lynx-CustomFit™ Aramid Shears |
Resources
Fiber Optic Ribbon Termination Resources
Standard Riser Ribbon Cable SRP
SP-F02-007 – Ribbon Access SRP
SP-F02-011 – Ribbon Splitting SRP
UCTS-001 Instructions
Optical Fiber Specifications
Sumitomo Electric SM PureBand-Plus Fiber Specification
Features
- Patented Peelable Ribbon Matrix Material for Easy Fiber Access
- 12-Fiber Ribbon Groupings for Ease and Compatibility with Multi-Fiber Connectors
- All-Dielectric Cable Construction Requires No Grounding or Bonding
- Flame-Retardant Outer Jacket
- Meets OFNR and CSA FT4 Specifications
Benefits:
- All Dry Cable Construction Contains No Messy Gel, Thereby Making the Installation Faster
- Superior Flexible Design for Indoor Routing
- RoHS Compliant