Indoor Riser Rated Tube Cable

These multi-tube cables are used for creating indoor tube cable infrastructures. They are UL OFNR listed for riser transitions between building floors. They are ideal for intrabuilding backbones.

Find a Distributor

Product Downloads

Product Information

Download

Specifications

PropertySpecification
Min. Bend Radius – During Installation20 x Cable OD
Min. Bend Radius – After Installation10 x Cable OD
Inner Tube ID0.24 in (6 mm)
Inner Tube OD0.32 in (8 mm)
Standard Reel Length3,000 ft (914.4 m)
2000 ft (609.6 m) [TC24TRC Only]
2,500 ft (762.0 m) [TC19TRC-1 Only]
Max. Reel Length3,000 ft (914.4 m)
2000 ft (609.6 m) [TC24TRC Only]
2,500 ft (762.0 m) [TC19TRC-1 Only]
Operation Temperature Range-4 to + 158°F (-20 to +70° C)
TestingUL 1666, cUL FT4, CSA FT4 Listed

Ordering Information

Standard Tube Cables

Part NumberTube Qty.Nominal Cable ODNominal WeightMax. Tensile Load
TC02TRC20.80 in (20.3 mm)140.0 lb/kft (208.3 kg/km)120 lb (534 N)
TC04TRC40.90 in (22.9 mm)210.0 lb/kft (312.5 kg/km)200 lb (890 N)
TC07TRC71.00 in (25.4 mm)310.0 lb/kft (461.3 kg/km)400 lb (1,780 N)
TC12TRC121.48 in (37.6 mm)480.0 lb/kft (714.3 kg/km)400 lb (1,780 N)
TC19TRC191.70 in (43.2 mm)574.0 lb/kft (854.2 kg/km)500 lb (2,225 N)
TC24TRC242.02 in (51.3 mm)793.0 lb/kft (1,180.1 kg/km)500 lb (2,225 N)
UL/CUL OFNR Rated Tube Cable/Single Jacket

Interlocking Armored Tube Cables

Part NumberTube Qty.Nominal Cable ODNominal WeightMax. Tensile Load
TC02TRC-121.08 in ( 27.4 mm)543.0 lb/kft (808.0 kg/km)500 lb (2,225 N)
TC04TRC-141.20 in (30.5 mm)748.0 lb/kft (1,113.1 kg/km)500 lb (2,225 N)
TC07TRC-171.39 in (35.3 mm)982.0 lb/kft (1,461.3 kg/km)600 lb (2,670 N)
TC12TRC-1121.73 in (43.9 mm)1,101.0 lb/kft (1,638.4 kg/km)600 lb (2,670 N)
TC19TRC-1192.03 in (51.6 mm)1,783.0 lb/kft (2,653.3 kg/km)600 lb (2,670 N)
Interlocked Glavanized Steel Armored (No Armor Over Jacket)

Features

  • Flame Resistant PVC Jacket Materials
  • Flame Barrier Tape
  • Ripcords
  • Cable Length Markings at 2 Foot Intervals
  • Tube ID Numbers Marked at 2 Inch Intervals
  • UL 1666 OFNR / CUL FT4
  • All-Dielectric
  • Meets ICEA, TIA and UL Standards