INSTRUCTIONS: Create a part number by using this character set. If needed, please refer to the Ordering Information section for the full configuration table. To ensure you are seeing the most up-to-date information, please remember to clear cache on your browser.

C [ Z ] – [ 1 ] [ 222 ] [ 3 ] [ 4 ] [ 5 ] [ 6 ] [ 7 ] [ 8 ] [999 ] [ U ] – [ X ] [ Y ] [ P ]

(21 characters minimum. More if exact length or other custom configuration.)

1. Click on the dropdown menus to select your options.
2. After selecting all dropdown options, click the “Create Part Number” button to generate a unique part number along with its corresponding product description.
3. To add additional products to your list:
a: Click “Add Another Product” to clear all previous fields selected to create the next part number.
b: Click “Augment Last Part Number” to retain all previous fields selected and update Length or Fiber Type to create the next part number.

If you have any questions or need assistance, please don’t hesitate to contact our Inside Sales team for help at 800-358-7378 or by filling out the Contact Us Form below.

Cable – Connectors
[z] Polarity/Fiber Orientation (Single)

For diagrams and a further explanation of Crossover Type and Straight Through Type Assemblies click on the Cable Assembly Guide.

[Z] Polarity/Fiber Orientation (Multi/Single Fiber)

For diagrams and a further explanation of Crossover Type and Straight Through Type Assemblies click on the Cable Assembly Guide.

[Z] Polarity/Fiber Orientation (Multi-Fiber)

For diagrams and a further explanation of Crossover Type and Straight Through Type Assemblies click on the Cable Assembly Guide.

[1] Fiber Type
[2] Fiber Count (Single Fiber)
[2] Fiber Count (Multi/Single Fiber)
[2] Fiber Count (Multi Fiber)
[3] Cable Design (Single)
[3] Cable Design (Multi/Single)
[3] Cable Design (Multi/Single)
[3] Cable Design (Multi)
[3] Cable Design (Multi)
[4] Armor Type
[5] Cable Jacket/Flame Retardancy Rating
[6] Subunits (Furcation Cord)
[6] Subunits (Furcation Cord)
[7] Connectors End A (Single)
[7] Connectors End A (Multi/Single)
[7] Connectors End A (Multi)
[8] Connectors End B (Single)
[8] Connectors End B (Multi/Single)
[8] Connectors End B (Multi)
[9] Length (see note below for Exact Length Assemblies)
Exact Length Cables: Assemblies that feature highly precise fiber lengths that provide more equal latency across the fibers housed within the assembly. For questions regarding exact length cables, contact our Inside Sales team directly via the “Contact Us Form" on this page.
[U] Length Unit
[X] End A Breakout Length (Single)
[X] End A Breakout Length (Multi/Single)
[X] End A Breakout Length (Multi)
[Y] End B Breakout Length (Single)
[Y] End B Breakout Length (Multi/Single)
[Y] End B Breakout Length (Multi)
[P] Pulling Eye

Product Cart

Augment Last Part Number

Use this function to retain all previous fields selected and update Length or Fiber Type to create the next part number.

Add Another Product

Use this function clear all previous fields selected to create the next part number.

Contact Information For Quote

Email *
Company
Name
Message / Questions

Contact Us Form

Email *
Company
Name
Message / Questions

Ordering Information

Instructions: Create a part number by using this character set and codes.

C [ Z ] – [ 1 ] [ 222 ] [ 3 ] [ 4 ] [ 5 ] [ 6 ] [ 7 ] [ 8 ] [999 ] [ U ] – [ X ] [ Y ] [ P ]

(21 characters minimum. More if exact length or other custom configuration.)

Z – POLARITY/PIN-OUT1 – FIBER TYPE2 – FIBER COUNT (3-DIGITS)3 – CABLE DESIGN4 – ARMOR TYPE5 – CABLE JACKET/FLAME
RETARDANCY RATING
Single Fiber Cable
A – Single Fiber Cable

Multi-Fiber Cable with Single-Fiber Connectors (LC, SC, ST, etc.)
A – A Connector to A Connector (Crossover Type; See Polarity Diagram)
B – A Connector to B Connector (Straight Through Type; See Polarity Diagram)

Multi-Fiber Cable with Multi-Fiber Connectors (MPO, MTP, etc.)
A – MPO/MTP Type A
B – MPO/MTP Type B
C – MPO/MTP Type C
D – MPO/MTP SM Type B (With Window Up Key Down)
G – 40G/400G Type B (Outer 8F out of 12F)
H – 40G/400G Type A (Outer 8F out of 12F)
1 – MPO24/MTP24 Config 1
2 – MPO24/MTP24 Config 2
3 – MPO24/MTP24 Config 3
4 – MPO24/MTP24 Config 4

1 – OM1 (62.5 μm)
2 – OM2 (50 μm)
3 – OM3 (50 μm)
4 – OM4 (50 μm)
5 – OM5 (50 μm)
8 – SM (G.657.A2)
9 – SM (G.657.A1)

001 – 1f
002 – 2f
004 – 4f
006 – 6f
008 – 8f
012 – 12f
016 – 16f
024 – 24f
036 – 36f
048 – 48f
050 – 50f
060 – 60f
072 – 72f
096 – 96f
144 – 144f
288 – 288f
432 – 432f
576 – 576f
864 – 864f
P – Pliable Ribbon (250μm)
Q – Pliable Ribbon (200μm)
A – Flat Ribbon (250μm)
B – Flat Ribbon (200μm)
X – Loose Buffer (200μm)
Y – Loose Buffer (250μm)
Z – Tight Buffer (900μm)
N – No Armor
L – Interlocking Armor
M – Micro Armor
A – OSP
B – Riser
C – Indoor/Outdoor Riser
D – LSZH (Low Smoke
Zero Halogen)
E – Riser LSZH
F – Indoor/Outdoor Riser LSZH
G – Plenum
H – Indoor/Outdoor Plenum
2 – B1ca
3 – B2ca
4 – Cca
5 – Dca
6 – SUBUNITS
(FURCATION CORD)
7 – CONNECTOR END A8 – CONNECTOR END B9 – LENGTH (3-DIGITS)U – LENGTH UNIT
C – 1.6 mm
T – 2.0 mm
X – 3.0 mm
9 – 900 μm
V – SEL Option
D – Not Applicable
5 – MPO (Male/Pinned), 12 Fiber, Low Loss
6 – MPO (Male/Pinned), 12 Fiber, Std Loss
7 – MPO (Female/Unpinned), 12 Fiber, Low Loss
8 – MPO (Female/Unpinned), 12 Fiber, Std Loss
0 – MPO (Female/Unpinned), 24 Fiber, Low Loss
W – MPO (Female/Unpinned), 24 Fiber, Std Loss
9 – MPO (Male/Pinned), 24 Fiber, Low Loss
Z – MPO (Male/Pinned), 24 Fiber, Std Loss
1 – MTP (Male/Pinned), 12 Fiber, Low Loss
M – MTP (Male/Pinned), 12 Fiber, Std Loss
2 – MTP (Female/Unpinned), 12 Fiber, Low Loss
Y – MTP (Female/Unpinned), 12 Fiber, Std Loss
4 – MTP (Male/Pinned), 24 Fiber, Low Loss
P – MTP (Male/Pinned), 24 Fiber, Std Loss
3 – MTP (Female/Unpinned), 24 Fiber, Low Loss
N – MTP(Female/Unpinned), 24 Fiber, Std Loss
L – LC, MM/SM, DX
Q – LC, MM/SM, SX
A – LC/APC, DX
E – LC/APC, SX
R – LC-UNIBOOT (Reversible/No Pull Tab)
G – LC-UNIBOOT (Reversible w/ Pull Tab)
S – SC, MM/SM, DX
V – SC, MM/SM, SX
B – SC/APC, DX
H – SC/APC, SX
F – FC, MM/SM
C – FC/APC
T – ST, MM/SM
X – BARE END (Open/Blunt)
5 – MPO (Male/Pinned), 12 Fiber, Low Loss
6 – MPO (Male/Pinned), 12 Fiber, Std Loss
7 – MPO (Female/Unpinned), 12 Fiber, Low Loss
8 – MPO (Female/Unpinned), 12 Fiber, Std Loss
0 – MPO (Female/Unpinned), 24 Fiber, Low Loss
W – MPO (Female/Unpinned), 24 Fiber, Std Loss
9 – MPO (Male/Pinned), 24 Fiber, Low Loss
Z – MPO (Male/Pinned), 24 Fiber, Std Loss
1 – MTP (Male/Pinned), 12 Fiber, Low Loss
M – MTP (Male/Pinned), 12 Fiber, Std Loss
2 – MTP (Female/Unpinned), 12 Fiber, Low Loss
Y – MTP (Female/Unpinned), 12 Fiber, Std Loss
4 – MTP (Male/Pinned), 24 Fiber, Low Loss
P – MTP (Male/Pinned), 24 Fiber, Std Loss
3 – MTP (Female/Unpinned), 24 Fiber, Low Loss
N – MTP(Female/Unpinned), 24 Fiber, Std Loss
L – LC, MM/SM, DX
Q – LC, MM/SM, SX
A – LC/APC, DX
E – LC/APC, SX
R – LC-UNIBOOT (Reversible/No Pull Tab)
G – LC-UNIBOOT (Reversible w/ Pull Tab)
S – SC, MM/SM, DX
V – SC, MM/SM, SX
B – SC/APC, DX
H – SC/APC, SX
F – FC, MM/SM
C – FC/APC
T – ST, MM/SM
X – BARE END (Open/Blunt)
001 – 001-999+F – Feet
M – Meters
I – Inch
X – END A BREAKOUT LENGTHY – END B BREAKOUT LENGTHP – PULLING EYEE0.5 – FOR EXACT LENGTH ONLY
1 – 18 in (457 mm) – No Stagger
2 – 24 in (609 mm) – No Stagger
3 – 36 in (914 mm) – No Stagger
4 – 48 in (1,219 mm) – No Stagger
5 – 60 in (1,524 mm) – No Stagger
6 – 72 in (1,828 mm) – No Stagger
7 – 16 in (406 mm) – No Stagger
8 – 12 in (305 mm) – No Stagger
A – 18 in (457 mm) – Subunit Stagger
B – 24 in (609 mm) -Subunit Stagger
C – 36 in (914 mm) -Subunit Stagger
D – 48 in (1,219 mm) -Subunit Stagger
E – 60 in (1,524 mm) -Subunit Stagger
F – 72 in (1,828 mm) -Subunit Stagger
H – 18 in (457 mm) -Fiber Pair Stagger
J – 24 in (609 mm) -Fiber Pair Stagger
K – 36 in (914 mm) -Fiber Pair Stagger
L – 48 in (1,219 mm) -Fiber Pair Stagger
M – 60 in (1,524 mm) -Fiber Pair Stagger
N – 72 in (1,828 mm) -Fiber Pair Stagger
Q – 18 in (457 mm) -Subunit and Fiber Pair Stagger
R – 24 in (609 mm) -Subunit and Fiber Pair Stagger
S – 36 in (914 mm) -Subunit and Fiber Pair Stagger
T – 48 in (1,219 mm) -Subunit and Fiber Pair Stagger
U – 60 in (1,524 mm) – Subunit and Fiber Pair Stagger
V – 72 in (1,828 mm) -Subunit and Fiber Pair Stagger
X – No Breakout
1 – 18 in (457 mm) – No Stagger
2 – 24 in (609 mm) – No Stagger
3 – 36 in (914 mm) – No Stagger
4 – 48 in (1,219 mm) – No Stagger
5 – 60 in (1,524 mm) – No Stagger
6 – 72 in (1,828 mm) – No Stagger
7 – 16 in (406 mm) – No Stagger
8 – 12 in (305 mm) – No Stagger
A – 18 in (457 mm) – Subunit Stagger
B – 24 in (609 mm) -Subunit Stagger
C – 36 in (914 mm) -Subunit Stagger
D – 48 in (1,219 mm) -Subunit Stagger
E – 60 in (1,524 mm) -Subunit Stagger
F – 72 in (1,828 mm) -Subunit Stagger
H – 18 in (457 mm) -Fiber Pair Stagger
J – 24 in (609 mm) -Fiber Pair Stagger
K – 36 in (914 mm) -Fiber Pair Stagger
L – 48 in (1,219 mm) -Fiber Pair Stagger
M – 60 in (1,524 mm) -Fiber Pair Stagger
N – 72 in (1,828 mm) -Fiber Pair Stagger
Q – 18 in (457 mm) -Subunit and Fiber Pair Stagger
R – 24 in (609 mm) -Subunit and Fiber Pair Stagger
S – 36 in (914 mm) -Subunit and Fiber Pair Stagger
T – 48 in (1,219 mm) -Subunit and Fiber Pair Stagger
U – 60 in (1,524 mm) – Subunit and Fiber Pair Stagger
V – 72 in (1,828 mm) -Subunit and Fiber Pair Stagger
X – No Breakout
A – Pulling Eye on End A Only
B – Pulling Eye on End B Only
D – Pulling Eye on Both End
X – No Pulling Eye
E0.5 – Exact Length,+/- 0.5 inches
Example: A – 9 144 P N G D L L 250 F – 3 3 A | Part No. is: CA-9144PNGDLL250F-33A
Cable Assembly, Method A, SM, 144F, Pliable Ribbon, No Armor, Plenum, 900μm Furcation, LC/D to LC/D, 250 Feet Long, 36 inch Breakout Each End, Pulling Eye